Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 44(15-16): 1247-1257, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37079448

RESUMO

Capillary zone electrophoresis ultraviolet (CZE-UV) has become increasingly popular for the charge heterogeneity determination of mAbs and vaccines. The ε-aminocaproic acid (eACA) CZE-UV method has been used as a rapid platform method. However, in the last years, several issues have been observed, for example, loss in electrophoretic resolution or baseline drifts. Evaluating the role of eACA on the reported issues, various laboratories were requested to provide their routinely used eACA CZE-UV methods, and background electrolyte compositions. Although every laboratory claimed to use the He et al. eACA CZE-UV method, most methods actually deviate from He's. Subsequently, a detailed interlaboratory study was designed wherein two commercially available mAbs (Waters' Mass Check Standard mAb [pI 7] and NISTmAb [pI 9]) were provided to each laboratory, along with two detailed eACA CZE-UV protocols for a short-end, high-speed, and a long-end, high-resolution method. Ten laboratories participated each using their own instruments, and commodities, showing excellence method performance (relative standard deviations [RSDs] of percent time-corrected main peak areas from 0.2% to 1.9%, and RSDs of migration times from 0.7% to 1.8% [n = 50 per laboratory], analysis times in some cases as short as 2.5 min). This study clarified that eACA is not the main reason for the abovementioned variations.


Assuntos
Ácido Aminocaproico , Anticorpos Monoclonais , Anticorpos Monoclonais/análise , Eletroforese Capilar/métodos , Eletrólitos
2.
J Pharm Biomed Anal ; 56(1): 23-9, 2011 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-21620602

RESUMO

Measuring dissolution of a comparator drug overencapsulated in a hard gelatin shell is necessary when determining performance of the native and blinded formulations. However, the gelatin in the shell may form cross-links upon storage at stressed conditions, resulting in slow dissolution of the encapsulated drug. The aim of this study was to develop a dissolution approach for a hard-gelatin overencapsulated formulation of a comparator drug, erlotinib, which can overcome cross linking of the capsule shell. In this case, following the USP two-tier dissolution test by simply adding an enzyme did not dissolve the cross-linked capsules because the medium used in the method for erlotinib described in the FDA Dissolution Database contains sodium dodecyl sulfate that inhibits the activity of the enzyme. Changing the method by using different surfactants was not considered acceptable because it is preferable to closely follow the compendial method for the comparator. A two-step tier-2 method was developed as a solution, without significant change to the compendial method conditions. It uses 0.1N HCl + pepsin as the initial medium to help capsule break-up. SDS is added at 15 min after the testing starts to ensure dissolution of the drug. This may be a useful general approach for dealing with cross-linking in over-encapsulated comparators. A UV fiber optic spectrophotometer was used for in situ, real-time detection of the dissolution profile during method development studies. The fast sampling rate available with this type of detection was important in elucidating the events occurring during dissolution and determining the optimal time of the SDS addition.


Assuntos
Antineoplásicos/química , Cromatografia Líquida de Alta Pressão/métodos , Tecnologia de Fibra Óptica/métodos , Quinazolinas/química , Espectrofotometria Ultravioleta/métodos , Cápsulas , Química Farmacêutica , Reagentes de Ligações Cruzadas/química , Composição de Medicamentos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Cloridrato de Erlotinib , Gelatina/química , Solubilidade , Soluções , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...